Skip to Content

CO2, Temperature & Humidity Sensors

https://www.snsmiddleeast.ae/web/image/product.template/1405/image_1920?unique=44370e1
The RSCO2 Range: Featuring Carbon Dioxide Sensors, Temperature Sensors & Humidity Sensors, designed to monitor and measure vital indoor air quality environmental parameters with precision and reliability. Engineered to be used across residential, public, commercial, and light industrial settings, these sensors offer digital RS485 Bacnet MS/TP, Modbus RTU & analog outputs. Various thermistor outputs available.

0.00 AED 0.0 AED 0.00 AED

0.00

  • Sensors Required
  • Voltage
  • Display Type
  • Outputs

This combination does not exist.

Room Sensors Carbon Dioxide Sensors

Product Information

  • Available as CO2 only (carbon dioxide sensor only), CO2 & temperature or CO2, temperature & humidity.
  • Versatile Outputs: Delivering 3x 0-10V analog signals for CO2 (PPM), Temperature (°C or °F), and Humidity (% Relative), alongside digital RS-485 communication supporting Modbus RTU or BACnet MS/TP protocols.
  • Reliable Operation: Equipped with a VFC Relay for CO2 and a thermistor output for third-party temperature monitoring, ensuring seamless integration and dependable functionality.
  • Robust Construction: Designed for straightforward wall mounting with a 1/2” DIA rear entry and snap-offs for side trunking, encased in a durable ABS UL Flame retardant housing, assuring longevity and safety in diverse environments.
  • Flexible Power Options: Compatible with 12-24V AC/DC or 230VAC electrical systems.
  • Optimal Performance: Exhibiting rapid response times, quick warm-up periods, and excellent long-term stability, with minimal interference, guaranteeing accurate readings and consistent operation over time.
  • Covered by S&S Middle East 3 Year Warranty

Technical Specifications:

  • Temperature Monitoring: Offers a normal indication range of 32-122°F, with a swift response time of t63% @ 77°F in approximately 20 seconds, an accuracy of ±0.5° @ 50-113°F, and a resolution of 0.1°.
  • Humidity Sensing: Provides indication across a range of 0-100% RH, with a quick response time of t63% @ 77°F in about 8 seconds, an accuracy of ±2% @ 59-86°F (20-90%RH), and a resolution of 0.1%.
  • Carbon Dioxide Detection: Utilizes diffusion type NDIR sampling with an indication range of 400 – 5000ppm, boasting a response time of t90 <120s, and an accuracy of 5% FS @ 77°F, ensuring precise CO2 monitoring over its lifespan of > 5 years.
  • Backed by a standard 3-year manufacturer's warranty, proudly designed and manufactured in the UK. The RS Carbon Dioxide, Temperature & Humidity Room Sensor range offer unparalleled performance, reliability, and versatility for comprehensive air quality monitoring solutions.



(CO2) Carbon Dioxide Sensors Only

Product Code

SensorsVoltageDisplayOutputs

RSCO21

CO2 Only

24V

Blank Display

0-10V

RSCO21-BAC

CO2 Only

24V

Blank Display

0-10V & BACNET

RSCO21-MOD

CO2 Only

24V

Blank Display

0-10V & MODBUS

RSCO22

CO2 Only

24V

LED Display

0-10V 

RSCO22-BAC

CO2 Only

24V

LED Display

0-10V & BACNET

RSCO22-MOD

CO2 Only

24V

LED Display

0-10V & MODBUS

RSCO23

CO2 Only

24V

Display Screen

0-10V

RSCO23-BAC

CO2 Only

24V

Display Screen

0-10V & BACNET

RSCO23-MOD

CO2 Only

24V

Display Screen

0-10V & MODBUS

RSVCO21

CO2 Only

230V

Blank Display

0-10V

RSVCO21-BAC

CO2 Only

230V

Blank Display

0-10V & BACNET

RSVCO21-MOD

CO2 Only

230V

Blank Display

0-10V & MODBUS

RSVCO22

CO2 Only

230V

LED Display

0-10V

RSVCO22-BAC

CO2 Only

230V

LED Display

0-10V & BACNET

RSVCO22-MOD

CO2 Only

230V

LED Display

0-10V & MODBUS

RSVCO23

CO2 Only

230V

Display Screen

0-10V

RSVCO23-BAC

CO2 Only

230V

Display Screen

0-10V & BACNET

RSVCO23-MOD

CO2 Only

230V

Display Screen

0-10V & MODBUS

Carbon Dioxide (CO2) & Temperature Sensors

Product Code

SensorsVoltageDisplayOutputs

RSCO2T1

CO2 & Temp 

24V

Blank Display

0-10V

RSCO2T1-BAC

CO2 & Temp

24V

Blank Display

0-10V & BACNET

RSCO2T1-MOD

CO2 & Temp

24V

Blank Display

0-10V & MODBUS

RSCO2T2

CO2 & Temp

24V

LED Display

0-10V 

RSCO2T2-BAC

CO2 & Temp

24V

LED Display

0-10V & BACNET

RSCO2T2-MOD

CO2 & Temp

24V

LED Display

0-10V & MODBUS

RSCO2T3

CO2 & Temp

24V

Display Screen

0-10V

RSCO2T3-BAC

CO2 & Temp

24V

Display Screen

0-10V & BACNET

RSCO2T3-MOD

CO2 & Temp

24V

Display Screen

0-10V & MODBUS

RSVCO2T1

CO2 & Temp

230V

Blank Display

0-10V

RSVCO2T1-BAC

CO2 & Temp

230V

Blank Display

0-10V & BACNET

RSVCO2T1-MOD

CO2 & Temp

230V

Blank Display

0-10V & MODBUS

RSVCO2T2

CO2 & Temp

230V

LED Display

0-10V

RSVCO2T2-BAC

CO2 & Temp

230V

LED Display

0-10V & BACNET

RSVCO2T2-MOD

CO2 & Temp

230V

LED Display

0-10V & MODBUS

RSVCO2T3

CO2 & Temp

230V

Display Screen

0-10V

RSVCO2T3-BAC

CO2 & Temp

230V

Display Screen

0-10V & BACNET

RSVCO2T3-MOD

CO2 & Temp

230V

Display Screen

0-10V & MODBUS

Carbon Dioxide (CO2), Temperature & Humidity Sensors

Product Code

SensorsVoltageDisplayOutputs

RSCO2TH1

CO2 & Temp 

24V

Blank Display

0-10V

RSCO2TH1-BAC

CO2 & Temp

24V

Blank Display

0-10V & BACNET

RSCO2TH1-MOD

CO2 & Temp

24V

Blank Display

0-10V & MODBUS

RSCO2TH2

CO2 & Temp

24V

LED Display

0-10V 

RSCO2TH2-BAC

CO2 & Temp

24V

LED Display

0-10V & BACNET

RSCO2TH2-MOD

CO2 & Temp

24V

LED Display

0-10V & MODBUS

RSCO2TH3

CO2 & Temp

24V

Display Screen

0-10V

RSCO2TH3-BAC

CO2 & Temp

24V

Display Screen

0-10V & BACNET

RSCO2TH3-MOD

CO2 & Temp

24V

Display Screen

0-10V & MODBUS

RSVCO2TH1

CO2 & Temp

230V

Blank Display

0-10V

RSVCO2TH1-BAC

CO2 & Temp

230V

Blank Display

0-10V & BACNET

RSVCO2TH1-MOD

CO2 & Temp

230V

Blank Display

0-10V & MODBUS

RSVCO2TH2

CO2 & Temp

230V

LED Display

0-10V

RSVCO2TH2-BAC

CO2 & Temp

230V

LED Display

0-10V & BACNET

RSVCO2TH2-MOD

CO2 & Temp

230V

LED Display

0-10V & MODBUS

RSVCO2TH3

CO2 & Temp

230V

Display Screen

0-10V

RSVCO2TH3-BAC

CO2 & Temp

230V

Display Screen

0-10V & BACNET

RSVCO2TH3-MOD

CO2 & Temp

230V

Display Screen

0-10V & MODBUS


RSCO2 Datasheet - CO2 Only

RSCO2T Datasheet - CO2 & Temperature

RSCO2TH Datasheet - CO2, Temperature & Humidity

Merlin RS User & Installation Guide

 RSCO2 Room CO2 Monitor Consultant Specification

 RSCO2T Room CO2 & Temperature Monitor Consultant Specification

 RSCO2TH Room CO2, Temperature & Humidity Monitor Consultant Specification

Popular Applications

Commercial Spaces

Data 
Centers

Educational 
Buildings

Entertainment 
Centers

Healthcare
Buildings

Hospitality 
Spaces

Manufacturing
Spaces

Places Of

Worship

Residential
Buildings

Transportation
Hubs

Get in touch